1. volume single duct terminal units. Nailor Industries Inc. 2. 00 260 Days per Year 12 Hrs per DayNailor Industries Inc. AT37S - 3’ Long • for Models 37S and 37SST. Figure 2: Support Using Unistrut and Rods (Shown: Model 3001Q - Single Duct Figure 3: Support Using Optional Supplied Hanger Brackets (Shown: Model D30RWQ - Single Duct VAV Quiet Terminal Unit with Standard DissipativeThe terminal unit is typically located above the ceiling and can serve multiple spaces. The entire terminal unit shall be designed and built as a single unit. They have been specifically designed and tested for use with variable air volume single duct terminal units. D-Fan_Powered-VAV-2013_D-Fan_Powered-2005VAV-bwnew 6/25/13 3:15 PM Page D128 Title Nailor Industries Inc. Power consumption and energy savings for other terminal unit sizes and models will vary based on motor size, fan powered terminal unit model, inlet static and discharge static pressures. The fan powered options were energy savers for buildings from the very. Nailor Industries Inc. . Reduce the inlet pressure, if possible. ACC. Gus Faris is vice president, engineering at Nailor Industries in Kingwood, Texas. A mechanical engineer must consider several variables and equipment types when designing a VAV system. FAN POWERED TERMINAL UNITS C C136 FAN POWERED TERMINAL UNITS • 35N SERIES Performance Data PSC Motor Fan Curves – Airflow vs. F4 BYPASS TERMINAL UNITS F BYPASS TERMINAL UNITS Unique "Flow Diverter" Valve Nailor's 3400 Series Mark II bypass terminal units utilize a. 4. 4 - 17 - 20 VAV-FF TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: FIBER-FREE. reserves the right to change any information concerning product or pricing without notice. (702) 648-5400. I would like thank Dr. 3 - 12 - 18 3000 10 - 28 - 16 D30HQ Page 1 of 1. Page 1 of 4 Receiving Inspection After unpacking the assembly check it for shipping damage. VAV Terminal Units, Green Building products, Fan Coil. Because the fan is in series with the airflow, the DOAS system fan is only required to deliver the ventilation air to the terminal unit. Nailor Industries Inc. • 22 ga. 1. Country Of Origin. The installer cuts a rectangular hole in. ACC. Furnish and install Nailor 3000 Series Single Duct Variable Volume Terminal Units of the sizes and capabilities as indicated on the drawings. T3LN. 3. Optional discharge attenuators ensure further noise reductions downstream of the duct. Rep Locator. Whether the requirement calls for a constant or variable air volume (VAV) single duct terminal, an electric or hot water reheat option or requires basic attenuation, the 3000 Series terminal units deliver. Using the Nailor 35N parallel fan powered terminal unit catalog information we can look at the inlet size. The engineer must also consider how the terminal units are going to be. The Nailor product catalog is the ultimate industry resource for information. , ASSOCIATE EMBER ASHRAE. AT37SW - 3’ Long • for Models 37SW and 37SWST. The previous version addressed only variable air volume (VAV) air-handling systems and. Johnson Controls Parallel Fan Powered Variable Air Volume terminals are available from 100 to 4100 cfm, providing flexibility in performance ranges to meet a multitude of system design requirements. HPAS achieve this level of zone control much more cost-effectively than do zonal systems—a central system requires only a VAV terminal, while a zonal system requires an additional fan coil, ventilation air distribution, piping controls,VAV LINEAR FLOOR DIFFUSER CONTROL DIAGRAM UNDERFLOOR AIR DISTRIBUTION SYSTEMS VAV • COOLING ONLY • NON-DUCTED MODEL: NLD-VC Nailor Industries Inc. AT35SE - 3’ Long • for Models 35SE and 35SEST. g. Chilled Water terminal units and chilled beams each have their features and benefits for delivering comfort. 3 cfm Max. SCHEDULE TPE: PROECT: ENINEER: CONTRACTOR: FAN POWERED TERMINAL UNIT WITH EPIC ECM MOTOR SERIES FLOW • CONSTANT OR VARIABLE VOLUME MODELS: 35S, 35SW AND 35SE • UNIT SIZES 1 – 6 DATE B. Parallel Fan. Nailor Industries Inc. VAV Terminal Units. Choosing the right equipment for your VAV system is critical, but it is only part of creating the right solution. • Convert Mechanical Constant Volume Regulators to Low Pressure Digital, Analog Electronic or Pneumatic Controls. Designed for cooling only, cooling with reheat, heating only or heat/cool changeover applications. Chilled Water terminal units and chilled beams each have their features and benefits for delivering comfort. Electronic VAV Retrofit Kit. Nailor 3000 and 3100 Series Terminal Units are among the most versatile VAV boxes on the market, providing easy HVAC system integration with diverse control packages. The first fan-powered VAV terminal units were paral-lel style. The Single Duct relies 100% on airflow from the air handling unit. •Automatic reset high. (Air Control & Air Distribution products, VAV Terminal Units, Green Products, Electric Duct Heaters), Engineered. Dimensions are in inches (mm). 4 - 17 - 20 VAV-FF TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: FIBER-FREE. Product offerings include Air Control & Distribution products, VAV Terminal Units, Green Building products, Fan Coil Units, Electric Duct Heaters, Sound Attenuators, Air Handling Units, and Filter Housings. Model D30HQX - Single Duct Exhaust Terminal Unit Author: Nailor Subject:. • Convert Multizone Systems to Variable Air Volume. Aluminum construction. galvanized steel with round or flat oval inlets. Nailor manufactures a range of standard and custom design retrofit terminal units for all applications. 04 cfm per year. Non Fan Powered Units. (August 2008) Andrew Cramlet, B. Building Materials · Texas, United States · 444 Employees. Units shall be pressure independent with (DDC, analog electronic, pneumatic) controls. Single Duct Exhaust Terminal Unit with Dissipative Silencer - Hospital Grade - Super Quiet Model D30HQX Created Date: 7/6/2010 4:22:55 PM. SCHEDULE TPE: PROECT: ENINEER: CONTRACTOR: FAN POWERED TERMINAL UNIT WITH EPIC ECM MOTOR SERIES FLOW • CONSTANT OR VARIABLE VOLUME MODELS: 35S, 35SW AND 35SE • UNIT SIZES 1 – 6 DATE B. Nailor has completed and received ARI certification for our complete line of Single Duct, Dual Duct, Fan Powered and Bypass Terminal Units presented in this catalog. , ASSOCIATE EMBER ASHRAE. Designed for both stand-alone applications and integration with BACnet building automation systems, EZvav are precise P+I pressure-independent VAV controllers that are pre-configured for standard control sequences covering the vast majority of terminal-unit applications. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES. Reps Area Engineers Area. An example of the current sticker used is shown below:. Nailor 3000 Series Single Duct Terminal units are simply put, versatile. 3 - 12 - 18 3000 10 - 28 - 16 D30HQ Page 1 of 1. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES Performance Data • Hot Water Coil Models: 30RW, 30RWQ and 30HQW Unit Sizes 4, 5 and 6. galvanized steel with round or flat oval inlets. PMDC. 1 - 12 - 21 VAV-SL TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: STERI-LINER. Nailor• Convert Multizone Systems to Variable Air Volume • Convert Mechanical Constant Volume Regulators to Low Pressure Pneumatic, Analog Electronic or Digital Controls. A few of the updates include: Additional applications such as fan-coil units and central hot water and chilled water plants. When compared for adenine. The air handling unit will typically consist of a fan and a cooling coil. 3400. 33SZ, 33SZE, 33SZW • Fan Powered Chilled Water Terminal Units • Size 40, 50 & 55 • FN2 Enclosure Options & Accessories FN3 Remote Line Voltage Controls Enclosure for 35S(ST), 37S(ST), 38F, 38S Series Model Series 30X and 30HQX. date: july 22, 2011 . Nailor Industries Inc. Nailor Industries Inc. Dash (-) in space indicates a NC less than 20. • Mounted on VAV section inlet for quiet operation. Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an occupied space in either a constant volume or variable air volume (VAV) HVAC system. The first letter in the model number indicates control type (P is for pneumatic). During cooling, parallel units act the same as a. Nailor Subject: Terminal Units Steri-Liner Liner Options Sound Power Level Correction FactorsFAN POWERED TERMINAL UNITS C C131 FAN POWERED TERMINAL UNITS • 37S/37SST SERIES Performance Data • Hot Water Coil Models: 37SW and 37SWST • Low Profile • Series Flow. An integral modulating actuator provides variable air volume control in cooling applications for precise zone temperature control. Nailor 3000 Series Single Duct Terminal units are simply put, versatile. The VAV diffuser enables the control of airflow into a room with a connected thermostat. Turning the manual fan speed control counterclockwise will increase the fan speed; clockwise will decrease speed. reserves the right to change any information concerning product or pricing without notice. When Nailor first started manufacturing fan powered terminal units, we made our place in the market by increasing features and benefits on our standard units. Single Duct VAV Terminal Unit Proportional Electric Heating Coils: a. Nailor Industries Inc. Available in several configurations, each 3000 Series is VAV Selection: Series Fan Powered Terminal Unit Where the single duct units are sized using the inlet of the ductwork, a fan powered unit must choose an inlet size as well as a fan/unit size. q Fiber-free liner. 11 - 2 - 22 3000 3 - 13 - 18 D30RW-1 Page 1 of 2. A. Model Series 3210, 3230, and 3240. Available Sizes: 4 in. Model 36VRR Model 36VRS Model 36VR E RETROFIT TERMINAL UNITS an ASHRAE paper in 1989 claiming that this combination of fan powered terminal units and VAV air handlers was saving about 20% of the building energy at that time. After an extensive and intense period of research, design and development, Nailor have produced a line of fan powered terminals that satisfy the vast majority of requiremnts the HVAC industry demands. These. If the design included VAV diffusers in every office, maintaining constant pressure in the supply duct downstream of the terminal unit. 0 inch (51 mm) is required. Maximum Inlet Static Pressure, in H2O. The Group consists of several business units: Nailor Industries, Inc. SINGLE DUCT TERMINAL UNIT WITH DISSIPATIVE SILENCER HOSPITAL GRADE • SUPER QUIET. Nailor 3000 and 3100 Series Single Duct Terminal Units are for constant or variable air volume (VAV) applications. and a variable air volume damper to modulate primary air. Page 1 of 10 CTE-5100 Series Thermostats: The CTE-5100 series thermostats are designed to be used with the CSP-5002 controller actuator. reserves the right to change any information concerning product or specification without notice or obligation. 7 C C143 FAN POWERED TERMINAL UNITS • 35N SERIES Performance Data • Hot Water Coil Model: 35NW • Parallel Flow. If they comply with these Specifications, series fan powered VAV terminal units manufactured by one of the following manufacturers will be acceptable: 1. VAV Terminal Units - Section D - Fan Powered Terminal Units - (Supersedes July 16, 2013)FAN POWERED CHILLED WATER TERMINAL UNIT CONSTANT VOLUME • SENSIBLE COOLING (DOAS) MODELS: 33SZ, 33SZE AND 33SZW UNIT SIZE 30 (LOW PROFILE) Nailor Industries Inc. 8 - 15 - 11 VAV - DDDD DUAL DUCT TERMINAL UNITS LINER OPTIONS. CONTROL FEATURES: • Fast connection/wiring between units with RJ12 (phone jack) connections. Damper 38S Underfloor Fan Powered Model Series: 3100 Single Duct 3230 Dual DuctAbout Nailor; Nailor International Group; Airwaves; Promotional Items;. reserves the right to change any information concerning product or pricing without notice. reserves the right to change any information concerning product or specification without notice or obligation. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. • Digital VAV Terminal Units Catalog • July 24, 2018 (Supersedes: July 10, 2018 ) Author: Nailor Subject: Terminal. • 22 ga. One of the decisions when designing a VAV system is what type of terminal units to use in the system. Nailor manufactures its own electric heating coils. 3200 E Gowan Rd North Las Vegas NV 89030. Nailor Industries Inc. 11 - 19 - 12 VAV. 3 - 30 - 17 3000 8 - 3 - 09 D30RW-2. is known for our industry leading customer focused approach to providing…See this and similar jobs on LinkedIn. Model Series 3000 • Basic Unit 1. DATE B SERIES SUPERSEDES DRAWING NO. 1kw increments because we make our own elements. The new EZvav Digital Controls by Nailor bring simplicity to the Variable Air Volume (VAV) terminal unit market. Nailor Solutions. Single Duct Terminal Units Nailor Industries Inc. The Nailor product catalog is the ultimate industry resource for information. DUAL DUCT TERMINAL UNITS • 3200 SERIES DUAL DUCT TERMINAL UNITS B B6. model 35S. Nailor Industries Inc. 2. Nailor 3600 Series Retrofit Terminal Units are designed for all applications and are engineered to transform inefficient constant volume systems to present day variable air volume systems with low installation costs. AT35NE - 3’ Long • for Model 35NE. PEFM 4FSJFT 445 4UFBMUI Super Quiet, Series Flow (Constant Volume). today commercial building variable air volume A terminal units. Fan Powered Terminal Units • 33SZ, 35N, 35S, 37N and 37S Series • All sizes. 86) zinc. The units shall be provided with a primary variable air volume damper that controls the air quantity in response to a (electronic, pneumatic) thermostat. reserves the right to change any information concerning product or specification without notice or obligation. Model Number. Terminal units are used within a Variable Air Volume (VAV) System to control the airflow and temperature delivered to a zone. Corrosion-Resistant Polypropylene Fans &. INSULATION CHARACTERISTICS. 36VRS • Retrofit Terminal Units • Square or Rectangular • Pressure Independent 36VRTR • Retrofit Terminal Unit • Round • Trane • Digital Controls 36VZR • Retrofit Terminal Units • Static Pressure Control •. The Price FDC-DOAS series fan powered terminal unit with a sensible cooling coil is an excellent solution for imparting large sensible loads on the zone when a Dedicated Outdoor Air System is utilized. 00. The portfolio includes aNailor Industries Inc reseres te rigt to cange an information concerning product or pricing witout notice. Overview. Designed for both stand-alone applications and integration with BACnet building automation systems, EZvav are precise P+I pressure-independent VAV controllers that are pre-configured for standard control sequences covering the vast majority of terminal-unit applications. . DESCRIPTION: The. reseres the right to change an information concerning product or pricing without notice. Nailor Industries, Inc. Perry Fiberglass Products, Inc. Of course, this was not solely due to the terminal units, but they were definitely instrumental to the system. To locate a Nailor representative in your area click "Rep Locator" link on the top of the page. community, asked a lot of questions and realized. Providing products that incorporate the desires and . Nailor 3000 also 3100 Series Terminal Units are among the most versatile VAV mail on the market, making easy HVAC system integration with diverse control packaged. Shallow plenums are common where zoning requirements limit building height. VAV-PRC012AD-EN 7 FeaturesandBenefits VariTrane Parallelfan-poweredunitsofferenergysavingswithintermittentfancontrol. NC Levels are calculated based on procedures as outlined on page B75. reserves the right to change any information concerning product or pricing without notice. FLOW WITH HOT WATER REHEAT CONTROL SEQUENCE: 1P3 + Q3 Nailor Industries Inc. CONTROL SEQUENCE: 7EL VARIABLE AIR VOLUME • COOLING WITH ON/OFF HOT WATER REHEAT AND AUXILIARY MINIMUM FLOW Sequence of. AT303 - Attenuator, 3 Foot Long. Single Duct Box. Available in 15 individual valve sizes to up to 15,000 cfm. Model 35N. D-Fan_Powered-VAV-2013_D-Fan_Powered-2005VAV-bwnew 6/25/13 3:15 PM Page D127 Title Nailor Industries Inc. Downstream Static Pressure 35S Series • Series Flow NOTES: • The ECM is pressure independent and constant volume in operation at factory or field set. Nailor Industries Inc. A Solid metal liner completely isolates the standard insulation and its raw edges from the. The following terminal units, accessories, and controllers are listed on OSP Special Seismic Certification Pre-Approval #OSP-0302-10:Parallel Fan Powered VAV (TVS) Download Specs. The VAV diffuser enables the control of airflow into a room with a connected thermostat. Dan Int-Hout is chief engineer at Krueger in. Krueger, Metalaire, and Nailor Industries for their financial contributions. TM UT TALLAT TAT DT 2 TM UT TALLAT TAT DT Manual priceindustriesco PRODUCT OVERVIEW Fan Powered Constant Volume Units – FDC-1-X, FDC-G2SINGLE DUCT VAV TERMINAL UNIT MODEL: 30RW CONTROL SEQUENCE: 3P3 (CSC-3011) Nailor Industries Inc. Claim this business. Page 1 of 2 Model Series: 3000 Single Duct 3210 Dual Duct 35S-OAI Series Fan Powered w/ O. E. In the bypass application, static pressure. In the parallel fan-powered terminal, the fan section is outside of the primary airstream and typically only runs in the heating mode. We listened in-depth to the engineering and contracting . 13. Nailor started Nailor Industries, Inc. Reduce the fan speed if possible or reselect the terminals for critical areas. IOMThe Nailor Model Series: 35S, 35SST, 37S, 37SST, 35N and 37N fan powered terminal unit performance data is presented in two forms. The units shall be provided with a primary variable air volume damper that controls the air quantity in. Specifying engineers as well as standard writers and building owners still Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. reserves the right to change any information concerning product or specification without notice or obligation. reserves the right to change any information concerning product or pricing without notice. reseres the right to change an information concerning product or pricing without notice. Using the Nailor 3000 series – 3001 model single channel unity as the basis of design, to catalog’d data can be used to determine the valid sizing for the application. Dimensions are in inches (mm). reserves the right to change any information concerning product or pricing without notice. Each Nailor Dual Duct terminal casing is constructed of 22 ga. , operating under Nailor International Group, is a privately held, family-owned company with headquarters located in Houston, TX. . Wireless HVAC Control. The Nailor UNI VAV diffuser enables the control of airflow into a place with a connect thermostat. It contains information on Nailor products and solutions as well as extensive Engineering and Application sections for each product category. Brand Name. 2. 11 - 2 - 22 3000 3 - 13 - 18 D30RW-1. Contact Hahn-Mason Air Systems today at (704)-523-5000. Nailor manufactures a range of standard and custom design retrofit terminal units for all. q By Others. 5 5 3 2 1 CFM l/s. PEFMT 4 445 XJUI 0"* 0VUEPPS "JS *OMFU Minimum Ventilation, Series Flow (Constant Volume) FOR VAV TERMINAL UNITS Nailor Industries Inc. Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an occupied space in either a constant volume or variable air volume (VAV) HVAC system. Room Temperature Sensor Option: TSD Digital Display (STE-8001W36) TSDO Digital Display w/Occupancy. Parallel Fan Powered units add a fan that is outside the flow of the primary air. 3 - 30 - 17 3000 8 - 3 - 09 D30RW-2. density Steri-Liner insulation. DATE B SERIES SUPERSEDES DRAWING NO. In the 1950s and into the 1960s, Houston was consid-ered the most air conditioned city in the United States. A mechanical engineer must consider several variables and equipment types when designing a VAV system. SUPERSEDES DRAWING NO. • Convert Constant Volume Dual Duct Systems to Variable Air Volume • Convert Multizone Systems to Variable Air Volume • Convert Mechanical Constant Volume Regulators to Low Pressure Pneumatic, Analog Electronic or Digital Controls. In a series unit (Fig. PEFM 4FSJFT 4 #BTJD 6OJU Quiet, Series Flow (Constant Volume). Nailor Industries Inc. Nailor Industries Inc. Attenuator. Quiet Units that include dissipative silencer and Hospital. Fan Powered - 35S (SST), 37S (SST), 37N. Series units contain a fan that is operational at the same time as the air handling unit. reserves the right to change any information concerning product or pricing without notice. In cases where there is a concern that the ventilation air will freeze the coil during winter, the AHU will have a heating coil. Nailor Industries Inc. Benefits. in a size 40 Price FDCG series terminal unit. Units shall be manufactured by Nailor Industries Inc. • Digital VAV Terminal Units Catalog • July 24, 2018 (Supersedes: July 10, 2018 ) Author: NailorOverview. Downstream Static Pressure. w. reserves the right to change any information concerning product or pricing without notice. reserves the right to change any information concerning product or pricing without notice. , The Ohio State University Chair of Advisory Committee: Dr. Designed for both stand-alone applications and for integration with BACnet building automation systems, EZvav are precise P+I pressure independent VAV controllersUnits shall be manufactured by Nailor Industries Inc. These. Its most frequent application is on small systems. Model Series 3400. Single Duct Terminal Units: Nailor 3000 and 3100 Chain Terminal Units are among an most versatile VAV boxes over the market, pro more. • Convert Constant Volume Dual Duct Systems to Variable Air Volume. Of course, this was not solely due to the terminal units, but they were definitely instrumental to the system. In this scenario, if all three VAV diffusers were wide open each office would supply 100 CFM. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 30HQ SERIES Performance Data • NC Level Application Guide. The VAV DOAS system will respond accordingly to manage the proper amount of ventilation air to the building. Catalogs are. DATE B SERIES SUPERSEDES DRAWING NO. DATE B SERIES SUPERSEDES DRAWING NO. reseres the right to change an information concerning product or pricing without notice. Inlet Size Airflow. Retrofit Terminal Units. I Fan-P T U deling. The engineer must also consider how the terminal units are going to be. • Digital VAV Terminal Units Catalog • November 1, 2022 (Supersedes: October 4, 2022 ) Author: Nailor Subject: Terminal Units Catalog Created Date: 11/21/2022 4:38:44 PM. VAV TERMINAL UNITS ALL-IN-ONE IOM CARNES COMPANY 448 S. reserves the right to change any information concerning product or specification without notice or obligation. Single Duct Terminal Unit With Hot Water Reheat - Digital or Analog Controls - Constant or Variable Volume - Pressure Independent - Models: D30RW and. Model 3210 is used when no terminal mixing is required. Nailor Industries Inc reseres te rigt to cange an information concerning product or pricing witout notice. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. Units shall reset to any flow between 0 and the maximum cataloged airflow as allowed by the specific controller. Fan powered variable air volume terminals are a popular choice for heating and cooling. Nailor 3000 Series Single Duct Variable Volume Terminal Units . New Product: LMHS-VP Learn about our new single duct terminal unit with a factory mounted valve package. Thefanenergizesonlyin. ONE smallish footprint makes these units simple to use and install in today‘s cramped mechanical spaces and. this sequence is intended to provide the design professional with a basic guideline of minimum requirements for typical vav air terminal units. Wireless Link For LonWorks, BACnet, Modbus & Ethernet Iinstallations. Nailor Industries Inc. Nailor Industries Inc. The terminal unit only responds to the conditions in the office with the thermostat. for VAV Terminal Units Nailor Industries Inc. Nailor 33SZ Series Fan Powered Chilled Water Terminal Units include a cooling induction coil to use in conjunction with a DOAS (dedicated outdoor air system) and is useful in a variety of commercial applications, such as office spaces, classrooms, critical environments and laboratories. PEDC. Whether the requirement calls for a constant or variable air volume (VAV) single duct terminal, an electric or hot water reheat option or requires basic attenuation, the 3000 Series terminal units deliver. This includes the load on the space, the static pressure in the ductwork, the types of terminal units, and the occupancies in the space. BY S FARIS, FE EER ASHRAE; DAN T-HOUT, FEL/FE EER ASHRAE; DES ’EAL, PH. Nailor Subject: Terminal Units Steri-Liner Liner Options Sound Power Level Correction FactorsFAN POWERED TERMINAL UNITS C C131 FAN POWERED TERMINAL UNITS • 37S/37SST SERIES Performance Data • Hot Water Coil Models: 37SW and 37SWST • Low Profile • Series Flow. No heater should be applied to exceed this temperature. Nailor offers three models of dual duct terminal units to meet a variety of applications. 00 $300. Single duct, parallel fan-powered, and series fan-powered units are connected to an air handling unit (AHU) that supplies the terminal units with cooled and dehumidified air. Nailor Industries Inc. Fan powered terminal units are designed to deliver a specific amount of air to the conditioned space to maintain the comfort for the occupants. Nailor Industries Inc. 5 - 12 - 22 VAV. A3400 E10 • Analog Electronic Controls • Control Sequence • VAV • Cooling with Time. REVIT. Reps Area Engineers Area. “We are a market leader in the HVAC industry. Low Profile. Figure 1: Support Using Hanger Straps (Shown: Model D30RW - Single Duct VAV Terminal Unit with Hot Water Heat). •Insulated coil element wrapper. UNITED STATES | CANADA | INTERNATIONAL. ACC. In 1971, Michael T. Nailor Superior Features and Efficiencies – Fan Powered VAV Terminal Units There are a lot of differences between Nailor and other fan powered VAV terminal. Nailor 3000 plus 3100 Series Single Duct VAV Depot Units key a cool and versatile build that results in a system component which has minimal pressure drop that reduces fan. INSTALLATION • All single duct terminal units with electric coils are designed to be mounted in a horizontal plane. FPTUs can be either constant or variable air ow. T3SQ-0. com 36VRS • Retrofit Terminal Units • Square or Rectangular • Pressure Independent 36VRTR • Retrofit Terminal Unit • Round • Trane • Digital Controls 36VZR • Retrofit Terminal Units • Static Pressure Control • Round Duct, Bypass or Branch Nailor 3000 Series Single Duct Terminal units are simply put, versatile. Nailor Subject: Models: 35SST, 35SWST & 35SEST Fan Powered Terminal Unit with EPIC ECM or PSC Motor - Stealth and FN2 option Keywords: Fan Powered Terminal Unit with EPIC ECM or PSC Motor and FN2 option - 'Stealth' - Series Flow - Constant or Variable Volume - Models: 35SST, 35SWST & 35SEST - Unit Sizes 1 - 6 Created Date:. HOW IT WORKS: The UNI2-VAV Electronic Thermostat is designed to wire to a factory mounted actuator board on a zone damper or VAV diff userThe Diamond sensor is standard on all Nailor VAV terminal units that are equipped with pressure independent controls. Features such as advanced sensor technology, a wide range of product sizes and air flows, low sound levels, increased hot water coil selections, and innovative options establish Price as an. , operating under Nailor International Group is a privately held, family owned company with Group headquarters located in Houston, TX. Grills. Room Temperature Sensor Option: TSD Digital Display (STE-8001W36) TSDO Digital Display w/Occupancy Motion Sensor (STE. The diffuser is manufactured from corrosion-resistant steel. Dallas was a close second. Dimensions are in inches (mm). Digital Variable Air Volume Diffuser. CONTROL SEQUENCE 1P3 • VAV COOLING WITH PROPORTIONAL HOT WATER HEAT •. • Slip and drive cleat duct connection on both ends.